>> Á¦Ç°¼Ò°³ >> Àü±Ø&¾Ç¼¼»ç¸® >> Hamilton Sensor
 
pH Sensor  (17)   ORP sensor  (4)   DO sensor  (1)  
ARC Sensor  (13)      
 

- Æ®·£½º¹ÌÅÍ°¡ ÇÊ¿ä¾ø´Â °£´ÜÇÑ ARC System

- VP 8.0 ¿¬°áÇìµå·Î µðÁöÅÐ/¾Æ³¯·Î±× Åë½Å ¼¾¼­

- ¿Â¶óÀÎ/¿ÀÇÁ¶óÀÎ º¸Á¤, ÀÚµ¿º¸Á¤ ±â´É

- PC, ARC View Handheld, ModBus RTU ÇÁ·ÎÅäÄÝÀ» ÀÌ¿ëÇÑ RS485 ÀÎÅÍÆäÀ̽º »ç¿ë °¡´É

- ARC Wi ¹«¼±¾Æ´äÅ͸¦ ÀÌ¿ëÇÑ ¹«¼± Åë½Å

- ARC Handheld Çϳª·Î ÃÖ´ë 31°³ ¼¾¼­ ¹«¼± ¸ð´ÏÅ͸µ

ARC System
 

Conductivity ARC sensor

Model NO.

242 720 (CONDUCELL PWSE ARC TC 1.5¡¯¡¯)

Range

0.01 to 2000 ¥ìS/cm

Measuring Method

2-pole contacting

Accuracy

¡¾ 3 %

Cell constant

c < 0.1 cm-1

Certificate

CE conformity

Wetted parts

FDA approved PEEK, EPDM o-Rings

Electrode Material

USF: Stainless Steel DIN 1.4435 / SS 316L

Temperature Range

- Analog interface: 0 to 110 ¡ÆC

- Digital interface: 0 to 130 ¡ÆC

Process pressure range

up to 10 bar at 130 ¡ÆC

Ư¡

- Steam sterilizable

- Autoclavable

- CIP

ÀÀ¿ë

- Monitoring of ultra-pure water

- Á¦¾à, ¹ÙÀÌ¿À °øÁ¤((WFI water, final rinse after CIP)

- ¹ßÀü¼Ò(º¸ÀÏ·¯¼ö)

- ¹ÝµµÃ¼ °øÁ¤

Process connection

1.5-inch TriClamp flange

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

Conductivity ARC sensor #242 720
 

Conductivity ARC sensor

Model NO.

242 159 (CONDUCELL 4USF ARC)

Range

1 to 300 000 ¥ìS/cm

Measuring Method

4-pole contacting

Accuracy

¡¾ 3 % at 1 to 100000 uS/cm

¡¾ 5 % at 100 to 300 mS/cm

Cell constant

c < 0.36 cm-1

Certificate

EHEDG*, CE conformity

Wetted parts

FDA approved PEEK, EPDM o-Rings

Electrode Material

USF: Stainless Steel DIN 1.4435 / SS 316L

Temperature Range

- Analog interface: -20 to 110 ¡ÆC

- Digital interface: -20 to 130 ¡ÆC

Process pressure range

up to 20 bar at 130 ¡ÆC

Ư¡

- Steam sterilizable

- Autoclavable

- CIP

ÀÀ¿ë

- Á¦¾à, ¹ÙÀÌ¿À °øÁ¤

- Food, À½¿ë¼ö

- È­ÇÐ

Process connection

PG 13.5

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

Conductivity ARC sensor #242 159
 

DO ARC sensor

Model NO.

243 115 (OXYGOLD B ARC)

Range

8 ppb ~ 40 ppm

Accuracy

¡¾ 2 % at 25 ¡ÆC

Required flow

¡Ã 0.1 m/s

Max. CO2 partial pressure

12 bar

Process pressure range

0 to 12 bar

Electrode system

Silver platinum combination

Electrolyte

OXYLYTE B, acidic

Temperature Range

- Analog interface: 0 to 100 ¡ÆC

- Digital interface: 0 to 130 ¡ÆC

Certificate

CE conformity

Ư¡

- ³ôÀº CO2 ³óµµ¿¡¼­ ÃøÁ¤

- Steam sterilizable

- Autoclavable

- CIP

ÀÀ¿ë

- À½¿ë¼ö, È­ÇÐ, ¸ÆÁÖ

Process connection

PG 13.5

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

DO ARC sensor #243 115 (OXYGOLD B ARC)
 

DO ARC sensor

Model NO.

243 100 (OXYFERM FDA ARC)

Range

10 ppb ~ 40 ppm

Accuracy

¡¾ 2 % at 25 ¡ÆC

Required flow

¡Ã 0.03 m/s

Max. CO2 partial pressure

0.01 bar

Process pressure range

0 to 4 bar

Electrode system

Silver platinum combination

Electrolyte

OXYLYTE, alkaline

Membrane

OPTIFLOW FDA

Temperature Range

- Analog interface: 0 to 100 ¡ÆC

- Digital interface: 0 to 130 ¡ÆC

Certificate

CE conformity

Wetted materials

Stainless steel 1.4435, EPDM and silicone with FDA approval

ÀÀ¿ë

- ¹ÙÀÌ¿À, Á¦¾à, Food & À½·á, È­ÇÐ

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

DO ARC sensor #243 100 (OXYFERM FDA ARC)
 

DO ARC sensor

Model NO.

243 163 (VISIFERM DO ARC)

Measuring Method

Optical DO(±¤ÇÐ ¹æ½Ä)

Range

4 ppb / 0.05 ~ 500 %

Accuracy

¡¾ 0.05 %-vol / 21 ¡¾ 0.2 %-vol / 50 ¡¾ 0.5 %-vol

Required flow

None

Oxygen consumption

None

Membrane

None

Polarization Voltage &time

None

Process pressure range

-1 to 12 bar

Temperature Range

-10 to 130 ¡ÆC

Certificate

CE conformity

Wetted materials

Stainless steel 1.4435, EPDM and silicone with FDA approval

Ư¡

- ¸âºê·¹ÀÎ ±³Ã¼ ¹× ±³Á¤ ¾øÀÌ °£´ÜÇÑ ¼¾¼­ ĸ ±³Ã¼

- CO2, SO2 ¿µÇâ ¾øÀ½

- ÀúÇ×·Â Yes : ¿¡Åº¿Ã, ¸Þź¿Ã, H2O2, ethylene oxide, beta-gamma irradiation

- ÀúÇ×·Â NO : ¿°¼Ò°¡½º, À¯±â¿ë¸Å(Ŭ·Î·ÎÆ÷¸§, Åç·ç¿£, ¾Æ¼¼Åæ, Çí»ê)

ÀÀ¿ë

- ¹ÙÀÌ¿À, Á¦¾à, Food & À½·á, ¼öó¸®Àå

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

DO ARC sensor #243 163 (VISIFERM DO ARC)
 

DO ARC sensor

Model NO.

243 110 (OXYGOLD G ARC)

Range

1 ppb ~ 40 ppm

Accuracy

¡¾ 2 % at 25 ¡ÆC

Required flow

¡Ã 0.1 m/s

Max. CO2 partial pressure

0.01 bar

Process pressure range

0 to 12 bar

Electrode system

Silver platinum combination

Electrolyte

OXYLYTE G, alkaline

Membrane

OPTIFLOW

Temperature Range

- Analog interface: 0 to 100 ¡ÆC

- Digital interface: 0 to 130 ¡ÆC

Certificate

CE conformity

ÀÀ¿ë

- º¸ÀÏ·¯¼ö, ¹ßÀü¼Ò, È­ÇÐ, Á¦¾à, ¹ÝµµÃ¼

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

DO ARC sensor #243 110 (OXYGOLD G ARC)
 

pH ARC sensor

Model NO.

243 154 (pHeasy ARC)

Range

0 ~ 14 pH

Zero-Point

0 ¡¾ 20 mV

Accuracy

¡¾ 0.02 pH at 25 ¡ÆC

Sample min conductivity

50 ¥ìS/cm

Temperature Range

- Analog interface : 0 to 110 ¡ÆC

- Digital interface : 0 to 130 ¡ÆC

Process pressure range

0 to 6 bar

Electrolyte

POLISOLVE

Reference System

HAMILTON EVEREF-L

Membrane glass

PHI glass

Diaphragm

2 SINGLE PORE

Certificate

CE conformity

Ư¡

- Steam sterilizable

- Autoclavable

- CIP

- º¸Á¤ ¾øÀÌ ¿¬¼Ó »ç¿ë °¡´É

- °Å²Ù·Î ¼³Ä¡ °¡´É

ÀÀ¿ë

- ¹ÙÀÌ¿À, Á¦¾à, Food & À½¿ë¼ö

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

pH ARC sensor #242 154 (pHeasy ARC)
 

pH ARC sensor

Model NO.

242 111 (POLILYTE Plus ARC)

Range

0 ~ 14 pH

Zero-Point

0 ¡¾ 20 mV

Accuracy

¡¾ 0.02 pH at 25 ¡ÆC

Sample min conductivity

2 ¥ìS/cm

Temperature Range

- Analog interface : 0 to 110 ¡ÆC

- Digital interface : 0 to 130 ¡ÆC

Process pressure range

0 to 6 bar

Electrolyte

POLISOLVE Plus

Reference System

HAMILTON EVEREF-L

Membrane glass

H glass

Diaphragm

2 SINGLE PORE

Certificate

CE conformity

Ư¡

- Steam sterilizable

- Autoclavable

- Àå½Ã°£ ¾ÈÁ¤ °¡´ÉÇÑ H glass

- °Å²Ù·Î ¼³Ä¡ °¡´É

ÀÀ¿ë

- È­ÇÐ, ¹°

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

pH ARC sensor #242 111 (POLILYTE Plus ARC)
 

pH ARC sensor

Model NO.

242 120 (EASYFERM Food ARC)

Range

0 ~ 14 pH

Zero-Point

0 ¡¾ 20 mV

Accuracy

¡¾ 0.02 pH at 25 ¡ÆC

Sample min conductivity

100 ¥ìS/cm

Temperature Range

- Analog interface : 0 to 110 ¡ÆC

- Digital interface : 0 to 130 ¡ÆC

Process pressure range

0 to 6 bar

Electrolyte

°¡¾ÐµÈ FOODLYTE

Reference System

HAMILTON EVEREF-F

Membrane glass

HB glass

Diaphragm

HP-COATRAMIC

Certificate

EHEDG*, Biocompatibility Test, CE conformity

Ư¡

- Steam sterilizable

- Autoclavable

- CIP

- ¼¼Á¤°ËÁõ EHEDG ¹× MDT »ýüÀûÇÕ Å×½ºÆ® ¿Ï·á

ÀÀ¿ë

- ¹ÙÀÌ¿À, Food & À½¿ë¼ö, Á¦¾à

Operating voltage

7~ 30 VDC max. 150 mW

Åë½Å

- Analog 1 : 420 mA for conductivity, programmable

Analog 2 : 420 mA for temperature, programmable

-Digital RS485 Interface : Modbus RTU protocol

pH ARC sensor #242 120 (EASYFERM Food ARC)
 
 1 [2]